Lambda Transmitter LT2

The LT2 Lambda transmitter is a universal, microprocessor based O2 measuring instrument for the direct measurement of O2 concentration in exhaust gases from oil and gas combustion facilities in the superstoichiometric domain ( λ >1), in conjunction with the LS2 Lambda probe.

In addition to O2 measurement, the LT2 Lambda transmitter also offers the following functions:

•  Measurement of flue gas and air temperature intake, and calculation of combustion efficiency
•  Detection of unburnt residue (CO/H2), shown as CO equivalent (COe)
•  Calculation and display of CO2 concentration
•  O2-regulation
•  Combustion chamber pressure regulation
•  Field bus connection

Downloadable File:

Fichier Français

Vue d’ensemble du système
LAMBDA LT2

Fichier Anglais

System Overview
LAMBDA LT2
Category: Lambda measuring transmitter
  • Certificates
Certificates
TUV-Bericht-Funktionale-Sicherheit-LT3F
SIL2-Confirmation-LT3-F

Similar products

Close

Lambda Transmitter LT1

Le LT1 est un appareil universel de mesure d’O2 á base du microprocesseur fondé sur la mesure directe de la concentration d’O2 du gaz d'échappement dans la plage sur stœchiométrique (λ> 1). En liaison avec la sonde LS2.    Avantage : ▪ Caractéristique de mesure Linéaire ▪ Faible temps de réponse t = 20 Secondes ▪ Etalonnage automatique à l’air ambiant ▪ Installation jusqu’à 1400 °C Benefits: ▪ Gaz de combustion ▪ Gaz de déchets industriels ▪ Atmosphères de four ▪ Gaz de process Fichier Téléchargeable :

Fichier Français

Vue d'ensemble du système
LAMBDA LT1

Fichier Anglais

System Overview
LAMBDA LT1
Quick view
Close

Transmitter NT1

Système de mesure LAMTEC NT1 avec KS2DNOx La solution complète innovante pour la mesure simultanée des NOx et O2 Le transmetteur NOx LAMTEC NT1, associé à la sonde combinée LAMTEC KS2DNOx, constitue un appareil de mesure à microprocesseur universel. Le transmetteur NOx NT1 a été spécialement développé pour la mesure simultanée de la concentration en O2 et des oxydes d'azote (NOx) dans les fumées des installations de combustion, dans la plage surstœchiométrique (λ > 1). La valeur NOx mesurée représente la somme de tous les oxydes d'azote (NO et NO2). Fichier Téléchargeable :

Fichier Français

Vue d'ensemble du système
Transmetteur NT1

Fichier Anglais

System Overveiw
Transmetteur NT1
Quick view
Close

Lambda Transmitter LT3-F

CO/O2 regulation – the best solution for O2 regulation for gas combustion. The LAMTEC Lambda Transmitter LT3-F is supplied exclusively with a user interface. The user interface (UI) is located on the front door and has the following functions:
•  Display of O2 and CO measurement values
• Measurement calibration.
• Information on the operating status of the probe/measurement, software version, CRC and serial number
• Settings, filter time, analog output, probe replacement, display, maintenance mode
Downloadable File:

Fichier Français

Vue d'ensemble du système
LAMBDA LT3-F

Fichier Anglais

System Overview
LAMBDA LT3-F
Quick view
Close

Lambda Transmitter LT3

Associé à la sonde combinée KS1D de LAMTEC, le LAMTEC LT3 est un appareil de mesure universel basé sur la technologie des microprocesseurs. Ce transmetteur a été spécialement développé pour la mesure et la détection simultanées de la concentration en O2 et des composés oxydants COe (CO/H2) dans les émissions de gaz de combustion des systèmes de combustion, dans la plage surstoechiométrique (λ > 1). La valeur mesurée COe (e = équivalent) est la somme des signaux de tous les composés oxydants émis, tels que CO et H2. La sonde LAMTEC LS2 peut également être utilisée pour mesurer uniquement l'oxygène (O2). Dans sa configuration de base, le LT3 est certifié SIL1. Advantages: •  Mesure de l’oxygène (O2) et détection des composants oxydants des gaz d’échappement (COe (CO/H2)) dans les fumées jusqu’à une température de 1 400 °C •  Plage de mesure de l’O2 pur : 0 à 21 vol. % •  Plage de mesure du COe : 0 à 10 000 ppm •  Insensible à l'air ambiant/extérieur (COe) •  Aucun conditionnement du gaz d'échantillon requis, mesure directement dans les fumées humides •  Temps de réponse à 60 % (T60), O2 < 3 secondes (non filtré), COe < 3 secondes (non filtré)
• Approved according to DIN EN 16340
• Basic configuration certified against SIL1
Downloadable File:

Fichier Français

Vue d'ensemble du système
LAMBDA LT3

Fichier Anglais

Vue d'ensemble du système
LAMBDA LT3
Quick view

Lamtec Maghreb: System and sensors for combustion techniques

Centrale offices n°63, Quartier Al Firdaous, I-M1 magasin n°7, Ain Sebaa, 20400 - Casablanca
Téléphone:+212 660458044 / +212 663728375
Email:mabdelhak@lamtecmaghreb.com
aabdelhak@lamtecmaghreb.com
Our Blogs
  • REGUL_BT300
    Oxygen Measuring System
  • LAMTEC
    Systems and Sensors for Combustion Techniques: Innovation by Lamtec
OUR CATEGORIES
  • Combustion Management
  • Ignition systems
  • Fault indicator
  • Measure
  • CO regulation
  • Actuator
  • BUS system
Quick Links
  • Home
  • About
  • Our Products
  • New
  • Contact Us
  • Devis Gratuit
Télécharger sur l'App Store Disponible sur Google Play
LAMTEC MAGHREB 2025 CREATED BY MEJ AGENCY
  • Home
  • About US
  • Our Products
  • Blogs
  • TRAINING
  • FREE QUOTE
  • en_USEN
    • fr_FRFR